Cp2 test 1 Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Cp2 test 1? On this page you'll find 31 study documents about Cp2 test 1.
Page 2 out of 31 results
Sort by
-
CP2 Exam 1 Questions & Answers 2024
- Exam (elaborations) • 6 pages • 2024
-
Available in package deal
-
- $7.99
- + learn more
CP2 Exam 1 Questions & Answers 2024 
 
 
VE = - ANSWER-TV x RR 
 
RPP= - ANSWER-HR x SBP 
 
what are some additional functional tests that can be done if can't do exercise test? - ANSWER-stress echo, sestambi, 6MWT (gives us HR, gait speed) 
 
cholesterol norm - ANSWER-120-200 
want 180 for heart disease patients 
 
HDL norm - ANSWER-40-60 but >60 is best 
under 40 is CAD risk 
 
LDL norm - ANSWER-<100 
100-129 is okay 
 
triglyceride norm - ANSWER-<150 mg/dL 
 
MB Index normal - ANSWE...
-
NACE CP2 Quiz 2 Questions and Answers (Verified Answers)Graded A+
- Exam (elaborations) • 7 pages • 2024
-
- $9.79
- + learn more
NACE CP2 Quiz 2 Questions and Answers (Verified Answers) 
A structure-to-electrolyte potential measures the potential difference between 
 
A. Two different structures acting as electrodes 
B. The structure and a standard reference electrode 
C. The structure and the anodes 
D. Two different points on the structure 
B. The structure and a standard reference electrode 
 
 
If 5.0 A of battery current passes through the outside leads of a 4-wire current span spaced at 30 m (100 ft), resulting in a...
-
NACE CP2 Quiz 3 Questions and Answers (Verified Answers) Graded A+
- Exam (elaborations) • 5 pages • 2024
-
- $9.69
- + learn more
NACE CP2 Quiz 3 Questions and Answers (Verified Answers) 
A mitigation control bond should be designed to 
 
1. carry the necessary current 
2. restrict the current to that required to mitigate the problem 
3. keep the current going in one direction if necessary 
4. return the potential on the interfered with structure to its pre-interference state 
All of the above 
 
 
A mitigation bond may cause more problems under which of the following conditions? 
 
1. Where the interfering structure bond ...
-
CP2 Exam 2 - Pulmonary Rehab Questions & Answers 2024
- Exam (elaborations) • 5 pages • 2024
-
Available in package deal
-
- $7.99
- + learn more
CP2 Exam 2 - Pulmonary Rehab Questions & Answers 2024 
 
 
exercise capacity and function, symptoms (specifically dyspnea), fatigue, health-related quality of life - ANSWER-What are the 4 major outcome areas that need to be assessed in pulmonary rehab? 
 
symptom-limited, submaximal, timed walking tests (6 minute, shuttle, etc) - ANSWER-Outcome measurements used to assess exercise capacity and function include: 
1. _______-_______ graded exercise test 
2. _______ exercise test 
3. _______ ____...
-
NACE CP2 – EXAM Question And Answers 2023-2024
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $8.99
- + learn more
NACE CP2 – EXAM Question And Answers Latest 
What is the cause of chalking in epoxy coating - Correct answer-UV or radiation exposure What is polymerization cured coating? - Correct answer-Two parts mixed together just prior to use Examples of non-convertible coatings - Correct answer-1. Chlorinated rubber 2. Vinyl 3. Acrylic 4. Bituminous Non-convertible curing def. - Correct answer-No chemical change during cure cycle Convertible curing def. - Correct answer-Some chemical change during cure...
Make study stress less painful
-
NACE CP2 Quiz 2 Questions and Answers (Verified Answers)|Graded A+
- Exam (elaborations) • 7 pages • 2024
-
- $9.69
- + learn more
NACE CP2 Quiz 2 Questions and Answers (Verified Answers) 
A structure-to-electrolyte potential measures the potential difference between 
 
A. Two different structures acting as electrodes 
B. The structure and a standard reference electrode 
C. The structure and the anodes 
D. Two different points on the structure 
B. The structure and a standard reference electrode 
 
 
If 5.0 A of battery current passes through the outside leads of a 4-wire current span spaced at 30 m (100 ft), resulting in a...
-
NACE CP2 Quiz 2 Questions and Answers 2024
- Exam (elaborations) • 12 pages • 2023
- Available in package deal
-
- $11.49
- + learn more
NACE CP2 Quiz 2 Questions and Answers 2024 
A structure-to-electrolyte potential measures the potential difference between 
A. Two different structures acting as electrodes 
B. The structure and a standard reference electrode 
C. The structure and the anodes 
D. Two different points on the structure - ANSWER ️️ B. The structure and a 
standard reference electrode 
If 5.0 A of battery current passes through the outside leads of a 4-wire current span 
spaced at 30 m (100 ft), resulting in a vo...
-
NACE CP2 Quiz 3 Questions and Answers (Verified Answers)
- Exam (elaborations) • 5 pages • 2024
-
- $9.59
- + learn more
NACE CP2 Quiz 3 Questions and Answers (Verified Answers) 
A mitigation control bond should be designed to 
 
1. carry the necessary current 
2. restrict the current to that required to mitigate the problem 
3. keep the current going in one direction if necessary 
4. return the potential on the interfered with structure to its pre-interference state 
All of the above 
 
 
A mitigation bond may cause more problems under which of the following conditions? 
 
1. Where the interfering structure bond ...
-
NACE CP2 Quiz 3 Questions and Answers (Verified Answers)
- Exam (elaborations) • 5 pages • 2024
- Available in package deal
-
- $9.50
- + learn more
NACE CP2 Quiz 3 Questions and Answers (Verified Answers) 
A mitigation control bond should be designed to 
 
1. carry the necessary current 
2. restrict the current to that required to mitigate the problem 
3. keep the current going in one direction if necessary 
4. return the potential on the interfered with structure to its pre-interference state 
All of the above 
 
 
A mitigation bond may cause more problems under which of the following conditions? 
 
1. Where the interfering structure bond ...
-
NACE CP2 Quiz 2 Questions and Answers (Verified Answers)
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $10.00
- + learn more
NACE CP2 Quiz 2 Questions and Answers (Verified Answers) 
A structure-to-electrolyte potential measures the potential difference between 
 
A. Two different structures acting as electrodes 
B. The structure and a standard reference electrode 
C. The structure and the anodes 
D. Two different points on the structure 
B. The structure and a standard reference electrode 
 
 
If 5.0 A of battery current passes through the outside leads of a 4-wire current span spaced at 30 m (100 ft), resulting in a...
Study stress? For sellers on Stuvia, these are actually golden times. KA-CHING! Earn from your study resources too and start uploading now. Discover all about earning on Stuvia