Journeyman Plumbing Test Study Guide - _____ = two fixture units - Answer- 1 gallon per minute of flow (drainage pipe) schedule _____ or heavier pipe shall be permitted to be threaded with does specifically designed for plastic pipe. - Answer- 80 2 ways you can test a drainage sy...

[Show more]

Preview 3 out of 17  pages

  • May 1, 2024
  • 17
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
Journeyman Plumbing Test Study Guide
-

_____ = two fixture units - Answer- 1 gallon per minute of flow

(drainage pipe) schedule _____ or heavier pipe shall be permitted to be threaded with does
specifically designed for plastic pipe. - Answer- 80

2 ways you can test a drainage system. - Answer- in its entirety or in sections.

a chemical waste system shall be ____ ____ from the sanitary drainage system. - Answer-
completely separated

a circuit vent connects to a horizontal drainage branch and vents 2 traps to a max of __ traps. -
Answer- 8

a clinical sink serving a soiled utility room shall not be a substitute for a ____ - Answer- service
sink

a clinical sink shall have what kind of trap? - Answer- an integral trap in which the upper
portion of a visible trap seal provides a water surface. should flush like a water closet.

a fixture supply pipe shall terminate not more than ____ - Answer- 30 inches from point of
connection to the fixture

a vent stack shall be required for each drainage stack that has more than _____ branch
intervals. - Answer- 5

a waste pipe is not required to be trapped if it receives only _____ and does not connect directly
to a sanitary drainage system - Answer- clear water waste

accessible plumbing fixtures shall be installed with ____, ____,____ and _____ in accordance
with ICC A117.1 - Answer- clearances, heights, spacing and areangements

air admittance valves without an engineered design shall not be utilized to vent ____ or _____ -
Answer- dumps or tanks of any type

air gaps shall comply with - Answer- ASME A112.1.2 or A112.1.3

all strainer plates on drain inlets shall be designed and installed so that all openings are..? -
Answer- not greater than 1/2 inch (12.7) in least dimension.

all water pressure tanks shall be provided with a _____ valve at the top of the tank that will
operate up to max water pressure of _____ psi and max temp of ____ - Answer- vaccum relief
200 psi
200°F

,Antisiphon devices for water heaters - Answer- an approved means, such as a cold water "dip"
tube with a hole at the top or a vaccum relief valve installed in the cold water supply line above
the top of the heater tank.

appliances containing evaporator or cooling coils must be provided with... - Answer-
condensate drain systems.

area around a urinal that should be waterproofed with a smooth, readily cleanable,
nonabsorbant material. - Answer- 2 feet in front of urinal lip and 4 feet above the floor and at
least 2 feet to each side.

backflow preventers shall not be located in areas subject to _____ - Answer- freezing.

bathtub waste and overflow outlets shall be connected to tubing or piping not less than _____ in
diameter. - Answer- 1 1/2 inch (38 mm)

bottom fed water heaters and bottom fed tanks connected to water heaters shall have a _____
______ valve installed. - Answer- vaccum relief

branch tubes shall not restrict the flow in the ___ - Answer- run tube

brass cleanout plugs shall only be permitted for use on _____ piping systems. - Answer-
metallic

Brazed joints shall be grazed with ____ - Answer- a filler metal conforming to AWS A5.8.

building (house) traps shall be ____ - Answer- prohibited.

building sewers 8 inches and larger shall have s manhole located not more than ____ from the
junction of building drain and building sewer, and intervals not less than ____ - Answer- 200
feet
400 feet

building sewers smaller than 8 inches shall have cleanouts at intervals of not more than ___ -
Answer- 100 feet

clean outside shall be same size as piping served except piping larger than ____ - Answer- 4
inches.
exeptions:
•p trap with slip or ground joint can serve as cleanout for pipe one size larger than p trap.
•cleanouts on stacks can be one size smaller than stack.

cleanout plugs shall be of ____ - Answer- brass, plastic, or other approved materials.

cleanouts for 6 inch and smaller piping shall be provided with a clearance of not less than ____
- Answer- 18 inches

cleanouts for 8 inch and larger piping shall be provided with a clearance not less than _____ -
Answer- 36 inches

, cleanouts with openings at a finished wall shall have the face opening located within ____ of the
finished walk surface. - Answer- 1 1/2 inch

condensate disposal piping shall maintain a horizontal slope in the direction of discharge not
less than - Answer- 1/8 unit vertical in 12 units horizontal (1 percent slope)

connections between the drain and floor outlet plumbing fixtures shall be made with a _____ -
Answer- floor flange or a waste connector and sealing gasket.

connections between the drain and wall hung water closets shall be made with ____ - Answer-
an approved extension nipple or horn adapter.

covers of gravity tanks shall be vented with a return bend vent pipe with an area not less than
___ - Answer- the area of the down feed riser pipe.

definition: a receptacle designed to collect surface or storm water from an open area - Answer-
area drain

definition: Backflow - Answer- pressure created by any means in the water distribution system,
which by being in excess of the pressure in the water supply mains causes a potential backflow
condition.

definition: branch - Answer- any part or the piping system except a riser, main or stack.

definition: cistern - Answer- a small covered tank for storing water for a home or farm.
generally stores rain water.

definition: cleanout - Answer- an access opening in the drainage system utilized for the
removal of obstructions.

definition: gray water - Answer- waste discharged from lavatories, bathtubs, showers, clothes
washers and laundry trays.

definition: hot water - Answer- temp greater than or equal to 110°F (43°C)

definition: indirect waste pipe - Answer- a waste pipe that does not connect directly with the
drainage system, but discharges into the drainage system through an air break or air gap into a
trap, fixture, receptor or interceptor.

definition: Leader - Answer- an exterior drainage pipe for conveying storm water from roof or
gutter drains to and approved means of disposal.

definition: offset - Answer- a combination of approved bends that makes two changes in
direction bringing one section of the pipe out of line but into a line parallel with the other section.

definition: ready access - Answer- that which enables a fixture, appliance or equipment to be
directly reached without the removal or movement of any panel, door or similar obstruction and
without the use of a portable ladder, step stool or similar device.

definition: relief vent - Answer- a vent whose primary function is to provide circulation of air
between drainage and vent systems.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Gurustudy. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $27.72. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

74735 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$27.72
  • (0)
  Add to cart